1740008.00
Instruction Guide
Line Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .115/240 VAC ± 10%
single phase, 50/60 Hz
Horsepower Range @ 115 VAC . . . . . . . . . . . . . . . . . . . . . .1/20 - 1/8 HP
Horsepower Range @ 240 VAC . . . . . . . . . . . . . . . . . . . . . .1/10 - 1/4 HP
Armature Voltage Range . . . . . . . . . . . . . . . . . . . . . . . . . . . .0 - 240 VDC
Maximum Armature Current (continuous) . . . . . . . . . . . . . . . . . . . . .3 ADC
Acceleration Time (no load) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 second
Deceleration Time (no load) . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 second
Speed Regulation (% of base speed) . . . . . . . . . . . . . . . . . . . . . . . . . .1%
Line Fuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5A, fast-acting
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.68 lb
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .5.50 in. x 3.50 in. x 3.20 in.
Ambient Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . .10°C - 40°C
SPECIFICATIONS
Vedere la pagina 0
1 2 3 4 5 6 ... 11 12

Sommario

Pagina 1 - Instruction Guide

1740008.00Instruction GuideLine Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .115/240 VAC ± 10%single phase, 50/60 HzHorsepow

Pagina 2 - LIMITED WARRANTY

8Regulation (IR COMP)The IR COMP (P503) trimpot sets the voltage gain needed tomaintain the set speed of a motor under load. If the motor does notmai

Pagina 3 - Safety Warnings

91/4 HP130 VDC2500 RPM1.80 ADCCURR. LIMIT IR COMPCURR. LIMIT IR COMPCURR. LIMIT IR COMPCURR. LIMIT IR COMPCURR. LIMIT IR COMPCURR. LIMIT IR COMPCURR.

Pagina 4 - Dimensions

LEESON ELECTRIC2100 Washington StreetGrafton, WI 53024-0241, U.S.A.TEL: (262) 377-8810 FAX: (262) 377-9025Document number 250–0255, Revision 1Prin

Pagina 5 - Mounting

LIMITED WARRANTYA. Warranty - LEESON Electric warrants that its products will be free from defects inmaterial and workmanship for a period of one (1)

Pagina 6 - Figure 2. Case Layout

1Safety WarningsThis symbol  denotes an important safety message.Please read these sections carefully before performing anyof the instructions conta

Pagina 7 - Operation

25.50 [140]POWER ONPUSH ON PUSH OFF3.20 [81]0.88 [22]2.28 [58]3.42 [87]3.51 [89]ALL DIMENSIONS ININCHES [MILLIMETERS]2.50 [64]1.82 [46]1.06 [27]Dimens

Pagina 8 - Figure 3. Drive Connections

3Mount the drives vertically or horizontally using the two mountingkeyholes on the back of the case (see Figure 2 on page 4). Thekeyholes are 2.5 inc

Pagina 9 - Calibration

4Figure 2. Case Layout

Pagina 10 - Current Limit (CURR. LIMIT)

5WiringOperationThe drive has three conduit holes on the bottom of the case and oneconduit hole on the back of the case (Figure 2). Connect externalw

Pagina 11 - 240 VAC INPUT

6MOTOR230 VACA2A1L2-2306A-ABC6A-ABCFU501P501MAXMINCURR.LIMITIR COMPP502 P503 P505FU502L2-115 L1115 VACFigure 3. Drive Connections

Pagina 12

7Minimum Speed (MIN)The MIN trimpot (P502) sets the minimum speed. Turn the speedadjust knob full CCW (but do not turn off) before calibrating the MI