In addition to standard 3-phase induction motors, the
following motor types may be used with FHP Series drives:
• Permanent split capacitor (PSC)
• Shaded pole
AC synchronous
Warning
Caution should be taken when operating fan-cooled
motors at low speeds because their fans may not
move sufficient air to properly cool the motor.
LEESON recommends “inverter-duty” motors when
the speed range is beyond 10:1.
The following motor types MAY NOT be used:
• Split phase
• Capacitor start
• Repulsion induction
• Series Universal AC/DC
Any motor with starting switch (centrifugal or relay)
and/or separate starting winding.
Important Information